Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 130
Use the show stack command or the show stack connection command to
verify the mixed stack configuration.
Brocade# show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6610-24F active 748e.f891.c5b8 128 local Ready
2 D ICX6610-48P standby 748e.f834.4800 0 remote Ready
3 D ICX6450-24 member 748e.f86d.7aa7 0 remote Ready
4 D ICX6450-24P member 748e.f8b0.7aa0 0 remote Ready
5 D ICX6450-24P member 748e.f8b0.7cc0 0 remote Ready
6 D ICX6450-48 member 748e.f8d4.02c0 0 remote Ready
7 D ICX6450-48 member 748e.f8d4.2300 0 remote Ready
8 D ICX6450-24P member 748e.f8b0.6c00 0 remote Ready
active standby
+---+ +---+
=2/6| 1 |2/1==2/6| 2 |2/1=
| +---+ +---+ |
| |
|------------------------|
active
--- +---+ +---+ +---+
( 1 )3/7==2/1| 6 |2/3==2/1| 7 |2/3==2/1| 8 |
--- +---+ +---+ +---+
active
--- +---+ +---+ +---+
( 1 )3/1==2/3| 3 |2/1==2/3| 4 |2/1==2/3| 5 |
--- +---+ +---+ +---+
Standby u2 - No hitless failover. Reason: hitless-failover not configured
Current stack management MAC is 748e.f891.c5b8
Note: no "stack mac" config. My MAC will change after failover.
Brocade#show stack connection
Probing the topology. Please wait ...
ICX6610-24F Router#
active standby
+---+ +---+
=2/6| 1 |2/1==2/6| 2 |2/1=
| +---+ +---+ |
| |
|------------------------|
standby active
--- +---+ +---+ +---+ ---
( 2 )3/1==2/1| 5 |2/3==2/1| 4 |2/3==2/1| 3 |2/3==3/1( 1 )
--- +---+ +---+ +---+ ---
active standby
--- +---+ +---+ +---+ ---
( 1 )3/7==2/1| 6 |2/3==2/1| 7 |2/3==2/1| 8 |2/3==3/7( 2 )
--- +---+ +---+ +---+ ---
trunk probe results: 10 links
Link 1: u1 -- u2, num=5
1: 1/2/1 (T0) <---> 2/2/6 (T1)
2: 1/2/2 (T0) <---> 2/2/7 (T1)
3: 1/2/3 (T0) <---> 2/2/8 (T1)
4: 1/2/4 (T0) <---> 2/2/9 (T1)
5: 1/2/5 (T0) <---> 2/2/10(T1)
Link 2: u1 -- u2, num=5
1: 1/2/6 (T1) <---> 2/2/1 (T0)
2: 1/2/7 (T1) <---> 2/2/2 (T0)
3: 1/2/8 (T1) <---> 2/2/3 (T0)
4: 1/2/9 (T1) <---> 2/2/4 (T0)
5: 1/2/10(T1) <---> 2/2/5 (T0)
Link 3: u1 -- u3, num=2
1: 1/3/1 (T2) <---> 3/2/3 (T1)
2: 1/3/2 (T2) <---> 3/2/4 (T1)
Link 4: u1 -- u6, num=2
1: 1/3/7 (T3) <---> 6/2/1 (T0)
2: 1/3/8 (T3) <---> 6/2/2 (T0)
Link 5: u2 -- u5, num=2
1: 2/3/1 (T2) <---> 5/2/1 (T0)
2: 2/3/2 (T2) <---> 5/2/2 (T0)
Link 6: u2 -- u8, num=2
1: 2/3/7 (T3) <---> 8/2/3 (T1)
Mixed Stacking
128
FastIron Ethernet Switch Stacking Configuration Guide
53-1003090-02