Field definitions for the show memory command

TABLE 5

Field

Description

Total DRAM

The size (in bytes) of DRAM

Dynamic memory The total number of bytes in dynamic memory, including the number of bytes that are

available (free, or unused), and the percentage of memory used.

Displaying traditional stack chassis information

The show chassis command displays chassis information for each stack unit. Output resembles the
following (in this example, a three member stack).

device# show chassis

The stack unit 1 chassis info:

Power supply 1 (NA - AC - Regular) present, status ok

Power supply 2 not present

Fan 1 ok

Fan 2 ok

Exhaust Side Temperature Readings:

Current temperature : 33.0 deg-C

Warning level.......: 85.0 deg-C

Shutdown level......: 90.0 deg-C

Intake Side Temperature Readings:

Current temperature : 31.0 deg-C

Boot Prom MAC: 0000.00e4.6e00

Management MAC: 0000.00e4.6e00

The stack unit 2 chassis info:

Power supply 1 (NA - AC - Regular) present, status ok

Power supply 2 not present

Fan 1 ok

Fan 2 ok

Exhaust Side Temperature Readings:

Current temperature : 32.5 deg-C

Warning level.......: 85.0 deg-C

Shutdown level......: 90.0 deg-C

Intake Side Temperature Readings:

Current temperature : 31.0 deg-C

Boot Prom MAC: 0000.00e3.11c0

The stack unit 3 chassis info:

Power supply 1 (NA - AC - Regular) present, status ok

Power supply 2 not present

Fan 1 ok

Fan 2 ok

Exhaust Side Temperature Readings:

Current temperature : 31.5 deg-C

Warning level.......: 85.0 deg-C

Shutdown level......: 90.0 deg-C

Intake Side Temperature Readings:

Current temperature : 32.0 deg-C

Boot Prom MAC: 0000.00db.e500

Syntax: show chassis

Field definitions for the show chassis command

TABLE 6

Field

Description

Power Supply 1

The status of the primary power supply.

Power Supply 2

The status of the secondary power supply, if present.

Fan 1 and Fan 2

The status of the cooling fans

Displaying traditional stack chassis information