Displaying traditional stack chassis information – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 66
Field definitions for the show memory command
TABLE 5
Field
Description
Total DRAM
The size (in bytes) of DRAM
Dynamic memory The total number of bytes in dynamic memory, including the number of bytes that are
available (free, or unused), and the percentage of memory used.
Displaying traditional stack chassis information
The show chassis command displays chassis information for each stack unit. Output resembles the
following (in this example, a three member stack).
device# show chassis
The stack unit 1 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 33.0 deg-C
Warning level.......: 85.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 31.0 deg-C
Boot Prom MAC: 0000.00e4.6e00
Management MAC: 0000.00e4.6e00
The stack unit 2 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 32.5 deg-C
Warning level.......: 85.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 31.0 deg-C
Boot Prom MAC: 0000.00e3.11c0
The stack unit 3 chassis info:
Power supply 1 (NA - AC - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 31.5 deg-C
Warning level.......: 85.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 32.0 deg-C
Boot Prom MAC: 0000.00db.e500
Syntax: show chassis
Field definitions for the show chassis command
TABLE 6
Field
Description
Power Supply 1
The status of the primary power supply.
Power Supply 2
The status of the secondary power supply, if present.
Fan 1 and Fan 2
The status of the cooling fans
Displaying traditional stack chassis information
64
FastIron Ethernet Switch Stacking Configuration Guide
53-1003090-02