Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 40
Error! port 3/4/1 is invalid
device(config-unit-3)# stack-port 3/2/1
To return both ports to stacking status, enter the no stack-port command on the single stacking port.
This converts both ports to stacking ports. By default, if both ports are stacking ports, they are
displayed by the system only when stacking is enabled. If only one port is configured as a stacking
port, the system always displays this port.
Using secure-setup to build an FCX traditional stack
You can use the secure-setup utility to build an FCX traditional stack by performing the following step.
Enter stack enable and stack secure-setup commands when you have designated the desired
stacking ports and connected your FCX units together, on stack unit 1, as shown in the following
output.
device# stack enable
device# stack secure-setup
device# Discovering the stack topology...
Available UPSTREAM units
Hop(s) Id Type MAC Address
1 new FCX648POE 0000.00d6.0511
2 new FCX624 0000.0099.0000
Enter the number of the desired UPSTREAM units (0-2)[0]: 2
Selected Topology:
Active Id Type MAC Address
1 FCX624POE 0000.00e5.0100
Selected UPSTREAM units
Hop(s) Id Type MAC Address
1 2 FCX648POE 0000.00d6.0511
2 3 FCX624 0000.0099.0000
Do you accept the unit ids (y/n)?: y
device# Election, was alone --> active, assigned-ID=1, total 3 units, my priority=128
Election, was active, no role change, assigned-ID=1, total 3 units, my priority=128
reset unit 2: diff bootup id=1
reset unit 3: diff bootup id=1
Election, was alone --> active, assigned-ID=1, total 3 units, my priority=128
Detect stack member 2 POE capable
Detect stack unit 2 has different startup config flash, will synchronize it
Detect stack unit 3 has different startup config flash, will synchronize it
Done hot swap: Set stack unit 3 to Ready
Done hot swap: Set stack unit 2 to Ready
Synchronize startup config to stack unit 2
Flash Memory Write (8192 bytes per dot).Synchronize startup config to stack unit 3
Flash Memory Write (8192 bytes per dot).POE: Stack unit 2 Power supply 1 with 4
10000 mwatts capacity is up
Stack unit 2 Power supply 2 is down
Stack unit 3 Power supply 1 is up
Stack unit 3 Power supply 2 is down
Config changed due to add/del units. Do write mem if you want to keep it
Election, was active, no role change, assigned-ID=1, total 3 units, my priority=128
device#
Config changed due to add/del units. Do write mem if you want to keep it
device# PoE Info: PoE module 1 of Unit 2 on ports 2/1/1 to 2/1/48 detected.
Initializing....
PoE Info: PoE module 1 of Unit 2 initialization is done.
device# show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role MAC Address Pri State Comment
1 S FCX624POE active 0000.00e5.0100
128 local Ready
2 D FCX648POE standby
0000.00d6.0511 0 remote Ready
3 D FCX624 member
0000.0099.0000 0 remote Ready
standby active
+---+ +---+ +---+
| 3 |3/1--3/1| 2 |2/1--2/1| 1 |
+---+ +---+ +---+
Current stack management MAC is 0000.00e5.0100
device# write mem
Write startup-config done.
Flash Memory Write (8192 bytes per dot) .Flash to Flash Done.
Using secure-setup to build an FCX traditional stack
38
FastIron Ethernet Switch Stacking Configuration Guide
53-1003090-02