Show chassis – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 152
Examples
The following example specifies two trunks on a backbone device that connect to a peripheral device in
a substack. The first trunk contains ports 1 and 2; the second trunk contains ports 7 and 8. In both
cases, the first port in the trunk is an odd-numbered port.
Brocade(config-unit-1)# peri-trunk 1/3/1 to 1/3/2
Brocade(config-unit-1)# peri-trunk 1/3/7 to 1/3/8
History
Release
Command History
08.0.00a
This command was introduced.
show chassis
Displays chassis information for each stack unit.
Syntax
show chassis
Command Output
The show chassis command output displays the following information.
Output field
Description
Power supply #
The presence, status, output type, model number, serial
number, and firmware version number of the power
supply units, if present.
Power supply # Fan Air Flow Direction
The air flow direction of the power supply unit.
Fan #
The presence, status, speed mode, and air flow direction
of the fan. The fan controlled temperature and
temperature thresholds.
MAC # Temperature Readings
The current temperature reading of the MAC device.
CPU Temperature Readings
The current temperature reading of the CPU.
sensor # Temperature Readings
The current temperature reading of the sensor.
Boot Prom MAC
The MAC address of the boot prom
Management MAC
The management MAC address, for the active controller
only.
Modes
Privileged EXEC mode
show chassis
150
FastIron Ethernet Switch Stacking Configuration Guide