beautypg.com

Displaying configured stacking ports – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual

Page 78

background image

priority 128

stack-trunk 1/2/1 to 1/2/2

stack-trunk 1/2/6 to 1/2/7

stack-port 1/2/1 1/2/6

stack unit 4

module 1 icx6610-48p-poe-port-management-module

module 2 icx6610-qsfp-10-port-160g-module

module 3 icx6610-8-port-10g-dual-mode-module

priority 100

stack-trunk 4/2/1 to 4/2/2

stack-trunk 4/2/6 to 4/2/7

stack-port 4/2/1 4/2/6

stack unit 5

module 1 icx6610-48-port-management-module

module 2 icx6610-qsfp-10-port-160g-module

module 3 icx6610-8-port-10g-dual-mode-module

priority 128

stack-trunk 5/2/1 to 5/2/2

stack-trunk 5/2/6 to 5/2/7

stack-port 5/2/1 5/2/6

stack enable

Syntax: show running-config

Field descriptions for the show running-config command

TABLE 14

Field

Description

stack unit #

The stack identification number for this unit.

module #

Identifies the configuration for modules on this unit.

priority

Indicates that a priority has been assigned to this stack unit

stack-trunk

Indicates the trunk configuration

Displaying configured stacking ports

The stacking ports may display in the output from the show running-config command in three
different ways.

1. When stacking is enabled, the output shows both stacking ports.

stack unit 1

module 1 fcx-24-port-management-module

module 2 fcx-cx4-2-port-10g-module

module 3 fcx-xfp-1-port-10g-module

stack-port 1/2/1 1/3/1

2. When stacking is not enabled, neither stacking port is displayed.

stack unit 1

module 1 fcx-24-port-management-module

module 2 fcx-cx4-2-port-10g-module

module 3 fcx-xfp-1-port-10g-module

3. If one stacking port is configured, that port will be displayed whether or not stacking is enabled.

stack unit 1

module 1 fcx-24-port-management-module

module 2 fcx-cx4-2-port-10g-module

module 3 fcx-xfp-1-port-10g-module

stack-port 1/3/1

Displaying configured stacking ports

76

FastIron Ethernet Switch Stacking Configuration Guide

53-1003090-02