Verifying a traditional stack configuration – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 48
Verifying a traditional stack configuration
Log in to the active controller and verify the stack information by entering the show running-config
and show stack or show stack detail commands. If your stack is configured properly, you should see
the following:
•
One active controller, one standby controller, and stack members.
•
All stack members show a status of Ready
The following output shows an example configuration of an FCX traditional stack.
device# show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role MAC Address Pri State Comment
2 S FCX648POE standby
0000.0002.0000 0 remote Ready
3 S FCX624POE member
0000.0003.0000 0 remote Ready
4 S FCX648 member
0000.0004.0000 0 remote Ready
5 S FCX648POE member
0000.0000.0000 0
remote Ready
8 S FCX648POE active
0000.0001.0000 128 local Ready
active standby
+---+ +---+ +---+ +---+
-2/1| 8 |2/2--2/1| 4 |2/2--2/1| 3 |2/2--2/1| 2 |2/2-
| +---+ +---+ +---+ +---+ |
|--------------------------------------------------|
Current stack management MAC is 0000.0001.0000
Results for ICX devices are similar, with an equals sign (=) to show connections between trunk ports,
rather than the hyphen symbol (-) showing connections.
The next example shows output from the show version command for the same FCX stack.
device# show version
Copyright (c) 1996-2009 Brocade Communications Systems, Inc.
UNIT 8: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359
(3578117 bytes) from Primary FCX06000a359.bin
SW: Version 06.0.00a359T7f1
UNIT 2: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359
(3578117 bytes) from Primary FCX06000a359.bin
SW: Version 06.0.00a359T7f1
UNIT 3: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359
(3578117 bytes) from Primary FCX06000a359.bin
SW: Version 06.0.00a359T7f1
UNIT 4: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359
(3578117 bytes) from Primary FCX06000a359.bin
SW: Version 06.0.00a359T7f1
Boot-Monitor Image size = 365257, Version:06.0.00T7f5 (grz06000)
HW: Stackable FCX648P-POE
==========================================================================
UNIT 2: SL 1: FCX-48G POE 48-port Management Module
P-ENGINE 0: type DB90, rev 01
P-ENGINE 1: type DB90, rev 01
==========================================================================
UNIT 2: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)
==========================================================================
UNIT 3: SL 1: FCX-24G POE 24-port Management Module
P-ENGINE 0: type DB90, rev 01
==========================================================================
UNIT 3: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)
==========================================================================
UNIT 3: SL 3: FCX-2XG 2-port 10G Module (2-XFP)
==========================================================================
UNIT 4: SL 1: FCX-48G 48-port Management Module
P-ENGINE 0: type DB90, rev 01
P-ENGINE 1: type DB90, rev 01
==========================================================================
Verifying a traditional stack configuration
46
FastIron Ethernet Switch Stacking Configuration Guide
53-1003090-02