Verifying a traditional stack configuration

Log in to the active controller and verify the stack information by entering the show running-config
and show stack or show stack detail commands. If your stack is configured properly, you should see
the following:

One active controller, one standby controller, and stack members.

All stack members show a status of Ready

The following output shows an example configuration of an FCX traditional stack.

device# show stack

alone: standalone, D: dynamic config, S: static config

ID Type Role MAC Address Pri State Comment

2 S FCX648POE standby

0000.0002.0000 0 remote Ready

3 S FCX624POE member

0000.0003.0000 0 remote Ready

4 S FCX648 member

0000.0004.0000 0 remote Ready

5 S FCX648POE member

0000.0000.0000 0

remote Ready

8 S FCX648POE active

0000.0001.0000 128 local Ready

active standby

+---+ +---+ +---+ +---+

-2/1| 8 |2/2--2/1| 4 |2/2--2/1| 3 |2/2--2/1| 2 |2/2-

| +---+ +---+ +---+ +---+ |

|--------------------------------------------------|

Current stack management MAC is 0000.0001.0000

Results for ICX devices are similar, with an equals sign (=) to show connections between trunk ports,
rather than the hyphen symbol (-) showing connections.

The next example shows output from the show version command for the same FCX stack.

device# show version

Copyright (c) 1996-2009 Brocade Communications Systems, Inc.

UNIT 8: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359

(3578117 bytes) from Primary FCX06000a359.bin

SW: Version 06.0.00a359T7f1

UNIT 2: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359

(3578117 bytes) from Primary FCX06000a359.bin

SW: Version 06.0.00a359T7f1

UNIT 3: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359

(3578117 bytes) from Primary FCX06000a359.bin

SW: Version 06.0.00a359T7f1

UNIT 4: compiled on Jun 17 2009 at 06:23:29 labeled as FCX06000a359

(3578117 bytes) from Primary FCX06000a359.bin

SW: Version 06.0.00a359T7f1

Boot-Monitor Image size = 365257, Version:06.0.00T7f5 (grz06000)

HW: Stackable FCX648P-POE

==========================================================================

UNIT 2: SL 1: FCX-48G POE 48-port Management Module

P-ENGINE 0: type DB90, rev 01

P-ENGINE 1: type DB90, rev 01

==========================================================================

UNIT 2: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)

==========================================================================

UNIT 3: SL 1: FCX-24G POE 24-port Management Module

P-ENGINE 0: type DB90, rev 01

==========================================================================

UNIT 3: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)

==========================================================================

UNIT 3: SL 3: FCX-2XG 2-port 10G Module (2-XFP)

==========================================================================

UNIT 4: SL 1: FCX-48G 48-port Management Module

P-ENGINE 0: type DB90, rev 01

P-ENGINE 1: type DB90, rev 01

==========================================================================

Verifying a traditional stack configuration

46

FastIron Ethernet Switch Stacking Configuration Guide

53-1003090-02