beautypg.com

Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual

Page 138

background image

Use the show running-config command to view the mixed stack configuration.
The following example shows the configuration of a mixed stack using the
manual configuration method in which all stack members are configured from
each individual device. The mixed stack contains two ICX 6610 devices in the
backbone and two substacks of three ICX 6450 peripheral devices each.

Brocade# show running-config

stack unit 1

peri-port 1/3/1

peri-port 1/3/2

peri-port 1/3/7

peri-port 1/3/8

exit

stack enable

Unit 2

stack suggested-id 2

stack unit 2

peri-port 2/3/1

peri-port 2/3/2

peri-port 2/3/7

peri-port 2/3/8

exit

stack enable

Unit 3

stack suggested-id 3

stack enable

Unit 4

stack suggested-id 4

stack enable

Unit 5

stack suggested-id 5

stack enable

Unit 6

stack suggested-id 6

stack enable

Unit 7

stack suggested-id 7

stack enable

Unit 8

stack suggested-id 8

stack enable

Use the show stack command to verify the mixed stack configuration.

Brocade# show stack

alone: standalone, D: dynamic config, S: static config

ID Type Role Mac Address Pri State Comment

1 S ICX6610-48P active 748e.f834.4800 0 local Ready

2 D ICX6610-24F standby 748e.f891.c5b8 0 remote Ready

3 D ICX6450-24 member 748e.f86d.7aa7 0 remote Ready

4 D ICX6450-24P member 748e.f8b0.7aa0 0 remote Ready

5 D ICX6450-24P member 748e.f8b0.7cc0 0 remote Ready

6 D ICX6450-48 member 748e.f8d4.02c0 0 remote Ready

7 D ICX6450-48 member 748e.f8d4.2300 0 remote Ready

8 D ICX6450-24P member 748e.f8b0.6c00 0 remote Ready

active standby

+---+ +---+

=2/6| 1 |2/1==2/6| 2 |2/1=

| +---+ +---+ |

| |

|------------------------|

standby active

--- +---+ +---+ +---+ ---

( 2 )3/7--2/1| 6 |2/3--2/1| 7 |2/3--2/1| 8 |2/3--3/7( 1 )

--- +---+ +---+ +---+ ---

active standby

--- +---+ +---+ +---+ ---

( 1 )3/1--2/1| 5 |2/3--2/1| 4 |2/3--2/1| 3 |2/3--3/1( 2 )

--- +---+ +---+ +---+ ---

peri-ports w/o link: 1/3/2, 1/3/8, 2/3/2, 2/3/8

Standby u2 - No hitless failover. Reason: hitless-failover not configured

Current stack management MAC is 748e.f834.4800

Note: no "stack mac" config. My MAC will change after failover.

Mixed Stacking

136

FastIron Ethernet Switch Stacking Configuration Guide

53-1003090-02