Displaying stack flash information, Displaying reliable ipc statistics for stack units – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 71
Displaying stack flash information
Use the show stack flash command to display information about flash memory for stack members, as
shown in this example output from an ICX 6610 switch.
device# show stack flash
There is no startup-config.old
Stack flash that was read in bootup:
ICX6610-48P, ID =4, role= active, pri=200, config=1, jumbo=X PPVLAN=X S2M=0 FIPS=X
stack p: [0]=4/2/1 [1]=4/2/6 default p: 4/2/1(5) 4/2/6(5), , , hash-chain=X vlan#=X
ve#=X stp#=X
active-chg=0
Current written stack flash:
ICX6610-48P, ID =4, role= active, pri=200, config=1, jumbo=X PPVLAN=X S2M=0 FIPS=X
stack p: [0]=4/2/1 [1]=4/2/6 default p: 4/2/1(5) 4/2/6(5), , , hash-chain=X vlan#=X
ve#=X stp#=X
active-chg=0
Syntax: show stack flash
Field descriptions for the show stack flash command
TABLE 11
Field
Description
ID
Device ID
role
The role of this device in the stack
priority
The priority of this device in the stack
config
Indicates the port state (up or down) and identifies the port by number (stack-ID/slot/port).
The rest of the fields are used for debug purposes only.
Displaying reliable IPC statistics for stack units
Use the show stack rel-ipc stats command to display session statistics for stack units. The following
output is observed on an ICX 6610 switch.
device# show stack rel-ipc stats
Reliable IPC statistics:
Global statistics:
Pkts rcvd w/no session: 0
Msgs rcvd w/no handler: 0
Unit statistics:
Unit 2 statistics:
Msgs sent: 41384 Msgs received: 14052, Pkt sends failed: 0
Message types sent:
[9]=21674, [10]=19703, [11]=2, [13]=5,
Message types received:
[9]=14016, [10]=2, [11]=28, [13]=6,
Session statistics: base-channel, unit 2, channel 0:
Session state: established (last established 15 hours 33 minutes 31 seconds ago)
Connections established: 1
Remote resets: 0, Reset packets sent: 0
Connection statistics (for current connection, if established):
Msgs sent: 14636, Msgs received: 14039
Atomic batches sent: 0, Atomic batches received: 0
Pkts sent: 30892, Pkts received: 30842
Msg bytes sent: 1828190, Msg bytes received: 1232988
Pkt bytes sent: 2659848, Pkt bytes received: 1763028
Flushes requested: 30, Suspends: 0, Resumes: 0
Packets sent with data (DAT), ACKs, and window updates (WND):
Other: 888, ACK: 14010, WND: 437, ACK+WND: 0
Displaying stack flash information
FastIron Ethernet Switch Stacking Configuration Guide
69
53-1003090-02