Displaying information about stack failover – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 119

4 S FCX624S member 0000.0000.0000 128 reserve
active standby
+---+ +---+ +---+
-1/3| 1 |1/5--1/5| 2 |1/3--1/5| 3 |1/3-
| +---+ +---+ +---+ |
| |
|-------------------------------------|
Standby unit 2: protocols ready, can failover or manually switch over
Current stack management MAC is 0000.0000.1100
NOTE
The text “can failover or manually switch over” was added for hitless stacking failover and switchover.
Displaying information about stack failover
Use the show stack failover command to view information about rapid failover.
Displaying information about link synchronization status
Use the show stack link-sync status command to view the status of the link synchronization. The
following command output is from an ICX 6610 device.
device#show stack link-sync status
STACKING_LINK_GLOBAL_CTRL messages sent: 0, received: 0
STACKING_LINK_INDIVIDUAL_CTRL messages sent: 359, received: 0
STACKING_LINK_STATUS messages sent: 22300, received: 128883
STACKING_POE_SCTRL messages sent: 0, received: 0
STACKING_POE_STATUS messages sent: 0, received: 0
global_ctrl_dest: ffffffff
individual_ctrl_dest: ee
status_dest: 30
Syslog messages for hitless stacking failover and switchover
Syslog messages are generated for the following events:
•
Switchover
•
Failover
•
Standby controller assignment
The following table lists the supported syslog messages.
Supported syslog messages
TABLE 19
Message level
Message
Explanation
Informational
Stack: Stack unit unit_number has
been assigned as STANDBY unit of
the stack system
Indicates that the unit has been
assigned as the standby controller.
Informational
Stack: Stack is operational due to
SWITCH-OVER
Indicates that a switchover has
occurred.
Informational
Stack: Stack is operational due to
FAIL-OVER
Indicates that a failover has
occurred.
Displaying information about stack failover
FastIron Ethernet Switch Stacking Configuration Guide
117