Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 144
connect 4/2/3
stack unit 4
module 1 icx6450-24p-poe-port-management-module
module 2 icx6450-sfp-plus-4port-40g-module
stack-trunk 4/2/1 to 4/2/2
stack-trunk 4/2/3 to 4/2/4
stack-port 4/2/1 4/2/3
connect 3/2/1
connect 5/2/3
stack unit 5
module 1 icx6450-24p-poe-port-management-module
module 2 icx6450-sfp-plus-4port-40g-module
stack-trunk 5/2/1 to 5/2/2
stack-trunk 5/2/3 to 5/2/4
stack-port 5/2/1 5/2/3
connect 2/3/1
connect 4/2/1
stack unit 6
module 1 icx6450-48-port-management-module
module 2 icx6450-sfp-plus-4port-40g-module
stack-trunk 6/2/3 to 6/2/4
stack-port 6/2/1 6/2/3
connect 1/3/7
connect 7/2/1
stack unit 7
module 1 icx6450-48-port-management-module
module 2 icx6450-sfp-plus-4port-40g-module
stack-trunk 7/2/1 to 7/2/2
stack-trunk 7/2/3 to 7/2/4
stack-port 7/2/1 7/2/3
connect 6/2/3
connect 8/2/1
stack unit 8
module 1 icx6450-24p-poe-port-management-module
module 2 icx6450-sfp-plus-4port-40g-module
no legacy-inline-power
stack-trunk 8/2/1 to 8/2/2
stack-trunk 8/2/3 to 8/2/4
stack-port 8/2/1 8/2/3
connect 2/3/7
connect 7/2/3
stack enable
stack rconsole-off
!
!
!
tftp-server 10.120.34.184 image-location /
ip route 0.0.0.0/0 10.20.69.129
!
logging console
The following sequence shows the stack unconfigure mixed-stack command
being executed on the active controller. After confirmation, all peripheral ports
and peripheral trunks are removed from the ICX 6610 devices. The peripheral
ICX 6450 devices recover their configurations from before they were members
of the mixed stack, and they are reloaded.
Brocade# stack unconfigure mixed-stack
All the peri-ports/trunks will be removed and all the ICX6450 units will recover
pre-mixed-stacking configuration. Are you sure? (enter 'y' or 'n'): y
Removed peri-ports from configuration: 1/3/1 1/3/7
Removed peri-trunks from configuration: 2/3/1-to-2/3/2 2/3/7-to-2/3/8
The show stack command is executed on the active controller. The output
shows that the ICX 6450 devices are no longer part of the mixed stack,
because the MAC addresses are all zeroes, the State column shows “reserve,”
and the device status in the Comment column does not show “Ready.”
The Role column still shows “member” because the active controller retains the
configuration of the former stack member in reserve so that it can form a stack
Mixed Stacking
142
FastIron Ethernet Switch Stacking Configuration Guide
53-1003090-02