Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 145
later if stack merge or stack formation happens. To remove a stack member from
the configuration, use the no stack id command.
Brocade# show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6610-24F active 748e.f891.c5b8 128 local Ready
2 S ICX6610-48P standby 748e.f834.4d14 0 remote Ready
3 S ICX6450-24 member 0000.0000.0000 0 reserve
4 S ICX6450-24P member 0000.0000.0000 0 reserve
5 S ICX6450-24P member 0000.0000.0000 0 reserve
6 S ICX6450-48 member 0000.0000.0000 0 reserve
7 S ICX6450-48 member 0000.0000.0000 0 reserve
8 S ICX6450-24P member 0000.0000.0000 0 reserve
active standby
+---+ +---+
=2/6| 1 |2/1==2/6| 2 |2/1=
| +---+ +---+ |
| |
|------------------------|
Will assign standby in 10 sec due to all ready
Standby u2 - No hitless failover. Reason: hitless-failover not configured
Current stack management MAC is 748e.f891.c5b8
Note: no "stack mac" config. My MAC will change after failover.
Verifying the pre-stacking configuration recovery
Use the show stack command to verify that peripheral devices are no longer
part of the mixed stack. The show stack command is executed on one of the
ICX 6450 devices that is no longer part of the mixed stack.
In the following example, the Role column shows “alone,” indicating that it is a
standalone device. This means that the device was a standalone device before
joining the mixed stack.
Brocade# show stack
***** Warning! stack is not enabled. *****
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6450-24P alone 748e.f8b0.6c00 0 local None:0
+---+
2/1| 1 |2/3
+---+
Current stack management MAC is 748e.f8b0.6c00
Note: no "stack mac" config. My MAC will change after failover.
In the following example, the Role column shows "active" "standby," or "member"
indicating that it these devices are part of a stack. This means that the devices
were part of a traditional stack before joining the mixed stack.
Brocade# show stack
alone: standalone, D: dynamic config, S: static config
ID Type Role Mac Address Pri State Comment
1 S ICX6450-24P active 748e.f8b0.6c00 128 local Ready
2 S ICX6450-48 standby 748e.f8d4.2300 0 remote Ready
3 S ICX6450-48 member 748e.f8d4.02c0 0 remote Ready
standby active
+---+ +---+ +---+
2/1| 3 |2/3--2/1| 2 |2/3--2/1| 1 |2/3
+---+ +---+ +---+
Standby u2 - No hitless failover. Reason: hitless-failover not configured
Current stack management MAC is 748e.f8b0.6c00
Note: no "stack mac" config. My MAC will change after failover.
Mixed Stacking
FastIron Ethernet Switch Stacking Configuration Guide
143
53-1003090-02