ZOLL M Series Defibrillator Rev R User Manual
M series, Service manual
Table of contents
Document Outline
- Preface
- Maintenance Tests
- Overview
- Before You Begin the Maintenance Tests
- Equipment that You Need to Perform the M Series Maintenance Tests
- Equipment You Need for the M Series Options Maintenance Tests
- 1.0 Physical Inspection of the Unit
- 2.0 Front Panel Button Test
- 3.0 3, 5, and 12 Leads Test
- 4.0 Power Supply Test (Optional)
- 5.0 Leakage Current Test
- 6.0 Paddles Test (If applicable)
- 7.0 Heart Rate Display Test
- 8.0 Calibrating Pulses on Strip Chart Test
- 9.0 Notch Filter Test
- 10.0 Heart Rate Alarm Test
- 11.0 Defibrillator Self Test
- 12.0 Synchronized Cardioversion Test
- 13.0 Shock Test
- 14.0 Summary Report Test
- 15.0 Advisory Message Test
- 16.0 Pacer Test
- 17.0 SpO2 Monitor Test for SpO2 Option
- 18.0 EtCO2 Monitor Test (for EtCO2 Option)
- 19.0 Temperature Test
- 20.0 IBP Monitoring Test
- 21.0 NIBP Transducer Calibration Test
- 22.0 NIBP Monitor Test
- 23.0 NIBP Volume Leak Test with Fluke Biomedical NIBP Analyzer
- 24.0 Bluetooth Test
- Troubleshooting
- Disassembly Procedures
- Overview
- Required Equipment
- Parts That May Need Replacing After Disassembly
- Safety Precautions
- Overview of Modules
- 1. Removing the ZIF Keeper
- 2. Removing the Front Panel
- 2A. Removing the Display
- 2B. Removing the Control Board
- 3. Removing the Upper Housing Assembly
- 4. Removing the System Board Assembly
- 5. Removing the Battery Interconn ect Board Assembly
- 6. Removing the High Voltage/ Charger Assembly
- 7. Removing the High Voltage Module Assembly
- 8. Removing the High Voltage Capacitor Assembly
- 9. Removing the System Interconn ect Board
- 10. Removing the Printer/ Recorder Motor
- 11. Removing the Lower Housing Assembly
- 12. Removing the Print Head Assembly
- 13. Removing the PCMCIA Card Slot Assembly
- 14. Removing the Paddle Release Latch
- Replacement Parts
- Functional Description
- Overview
- Main System Board
- Main System Board Functions
- Power Supply
- ECG Front End
- Multifunction Electrode (MFE)/PADS (System Board and High Voltage Module)
- CPU and EPU
- High Voltage Module
- Defibrillator Charging and Discharging
- High Voltage Capacitor Monitor
- Pacer/Defibrillator Control Signals
- Internal Discharge Resistor Module
- AC/DC Charger Module
- System Interconnect Module
- Stripchart Recorder
- PCMCIA Slots
- Front Panel and Controls PWBA
- M Series Options
- Isolated Power Supply Module
- 12 Lead Option
- Pulse Oximetry (SpO2)
- End Tidal Carbon Dioxide (EtCO2)
- Biphasic Waveform
- Appendix
- Index