Sequence Mode Display

Set up a Sequence Mode display by first enabling Sequence mode in the
Timebase Horizontal dialog. A Num Segments value must also be provided as
follows:

Touch the Timebase descriptor label.

In the Timebase dialog, touch the Sequence mode
button.

Select the Sequence tab. Under Acquisition Settings,
touch inside the Num Segments field and enter a
value from 2 to 500.

Under Touch inside the Timeout field and enter a
value from 10 ms to 100 s. Then check the Enable
Timeout
checkbox.

Under Display Settings, touch inside the Display
Mode
field and select a mode from the pop-up
menu.

NOTE: The maximum value that you can enter for Starting at depends on the
Num Segments value you entered under Acquisition Settings. It also depends
on the Num Seg Displayed value you entered. For example, if you had entered
a value of 500 in Num Segments, and a value of 10 in Num Seg Displayed, the
maximum value you can enter as a starting segment is 491so that 10 segments
can be seen.