12. Maintenance/Inspection

68

[Grease Nipple Positions]

z

ISDBCR, ISPDBCR

Model

Nipple diameter [mm]

Common to all models

‡

6.0

Caution: y Charging too much grease may increase the agitation resistance and cause the ball screw to

generate heat easily or allow excess grease on the ball screw to scatter around and dirty the

surroundings as the screw turns. Be sure to wipe off excess grease.

y

It is difficult to move actuators of short leads by hand. With these actuators, do not try to

move the actuator by force, but connect a controller and move the actuator by jog operation.

y

In case the grease got into your eye, immediately go to see the doctor to get an appropriate

care.

After finishing the grease supply work, wash your hands carefully with water and soap to

rinse the grease off.

z

SSPDACR

Model

Nipple diameter [mm]

SSPDACR-S

‡

3.5

SSPDACR-M

‡

6.0

SSPDACR-L

‡

6.0

Caution: In case the grease got into your eye, immediately go to see the doctor to get an appropriate

care.

After finishing the grease supply work, wash your hands carefully with water and soap to rinse

the grease off.

Grease nipple

for guide

Grease nipple

for ball screw

Grease nipple cap

Grease nipple (left side)

Remove the grommet to access the grease nipples.

After grease has been added, put back the grommet.