6. Installation

41

6.5 Suctioning for Clean Room Application

Actuators designed for clean room application can demonstrate performance corresponding to cleanliness class

10 (0.1 Pm or more per 1 ft

3

) by suctioning air from the suction joint. The suction flow rate at the rated speed of

each model is shown in the table below.

Reference Suction Flow Rates

Type

Thread lead

Suction flow rate

[NL/min]

4

15

8

30

ISDBCR-S

ISPDBCR-S

16

60

5

20

10

50

20

120

ISDBCR-M/MX

ISPDBCR-M/MX

30

180

10

50

20

120

ISDBCR-L/LX

ISPDBCR-L/LX

40

180

10

50

20

100

SSPDACR-S

30

150

10

60

20

110

SSPDACR-M

40

160

25

120

SSPDACR-L

50

180

x

Suction air from the quick joint of ‡12 in outer diameter provided on the side face of the actuator. Connect an

air tube to this joint and suction air using a vacuum pump, ejector, etc. Suction equipment must be provided by

the customer.