beautypg.com

4 reversed-home specification, 5 cable exit direction, 6 guide with ball retention mechanism – IAI America SSPDACR User Manual

Page 65

background image

10. Options

57

10.4 Reversed-home Specification

In the reversed-home specification, the home is located on the front side. This is indicated by “NM” in the model

number. If you wish to change the home direction after the delivery, consult IAI because the moving direction

parameter must be adjusted, as well as the encoder’s Z-phase on certain models.

10.5 Cable Exit Direction

The cable should exit in one of the following four

10.6 Guide with Ball Retention Mechanism

A spacer (retainer) is inserted between adjacent balls (steel balls) in the guide to reduce noise and achieve

smooth operation. This specification is indicated by “RT” in the model number.

There is no longer metal noise generated by colliding balls and thus noise is reduced. Since balls are aligned by

retainers, annoying noise decreases. Wear caused by friction between balls decreases, oil no longer runs out due

to contact, and lubricating oil collects at the retainers. Accordingly, operation becomes smooth.

Ball

Cable exit from the back on

the right

(Option model number: A3E)

Cable exit from the right

(Option model number: A3S)

Cable exit from the back on

the left

(Option model number: A1E)

Cable exit from the left

(Option model number: A1S)

Cable

Cable

Cable

Cable

Ball

Spacer (retainer)

This manual is related to the following products: