2. Specification

21

L

L

Mb or Mc direction

Direction of moment

Direction of allowable overhang

Ma direction

Mb direction

Mc direction

Ma direction

Size

[mm]

Reference position for

moment calculation

Reference position

2.5 Allowable Load Moment of the Actuator

(1) ISDB, ISPDB, ISDBCR, ISPDBCR

Allowable load moment (Nxm)

Allowable load moment (Nxm)

Size

Ma

Ma

Mb

Mc

Mb

Mc

Allowable overhang load (L)

S

143.8

205.4

336.0

28.4

40.2

65.7

Ma direction: 450

Mb or Mc direction: 450

M

341.5

487.0

796.5

69.6

99.0

161.7

Ma direction: 600

Mb or Mc direction: 600

MX

341.5

487.0

796.5

69.6

99.0

161.7

Ma direction: 600

Mb or Mc direction: 600

L

560.2

800.1

1325.3

104.9

149.9

248.9

Ma direction: 750

Mb or Mc direction: 750

LX

560.2

800.1

1325.3

104.9

149.9

248.9

Ma direction: 750

Mb or Mc direction: 750

Caution: Make sure the load installed on the actuator is not longer than the allowable overhang load length

(L). If the load is longer than L, vibration may occur or the settling time may increase depending on

the position of center of gravity position or weight of the work part.

If a load moment exceeding the allowable load moment is applied, not only the life of the guide will

become shorter but vibration or longer settling time may also result.

S

42.5

M

51.5

MX

51.5

L

61.5

LX

61.5

L mm