beautypg.com

Setting the home position, 1 home return, 2 factory-set home position – IAI America SSPDACR User Manual

Page 54: 3 changing the home direction

background image

9. Setting the Home Position

46

9. Setting the Home Position

9.1 Home Return

Home return involves the operation explained below:

[1] When a home return command is issued, the actuator moves (in the direction set by the applicable

parameter).

[2] The software detects the mechanical end in the return operation. If option L (home limit switch) is installed, the

mechanical end is detected by a sensor.

[3] The slider reverses its direction when the mechanical end or home limit switch is detected, after which the

Z-phase signal is detected and the position where this signal has been detected becomes the reference point.

[4] The slider travels further by the offset amount set by the applicable parameter, and this position becomes

home.

9.2 Factory-set Home Position

How much the motor would turn after the mechanical end or home limit switch is detected until the Z-phase signal

is generated has been adjusted prior to shipment.

The standard distance travelled by each slider after it reverses its direction upon detection of the mechanical end

or home limit switch, until stopping at the home position, is shown in the table below.

Model name

Home position from mechanical

stopper or home sensor

(approx. in mm)

ISDB, ISPDB, ISDBCR,

ISPDBCR-S/M/MX/L/LX

5 mm

SSPDACR-S

SSPDACR-M

5 mm

SSPDACR-L

10 mm

9.3 Changing the Home Direction

If the home direction is changed after the actuator has been delivered, the moving direction parameter must be

changed, and the encoder’s Z-phase may also need to be adjusted on some models. Contact IAI.

This manual is related to the following products: