E. status/command word bit usage, continued – Fairbanks FB2550 SERIES User Manual
Page 172

Section 9 Network Application Configuration
07/2012
172
51254 Rev. 3
E. STATUS/COMMAND WORD BIT USAGE, CONTINUED
LOAD SETPOINT 2
WORD 1
BIT 6
Command: Load setpoint 2 for this scale.
Status:
Switches to 1 when command is executed returns to zero when
command is cleared.
LOAD CELL STATUS
WORD 1
BITS 8,9,10,11,12
Command: Not applicable.
Status:
All cells are when the value is zero, else data indicates the number of
the failing or failed cell.
PRINT COMMAND:
WORD 1
BIT 14
Command: Print scale ticket
Status:
Switches to 1 when the command is recognized and resets after the
print cycle is complete and the command bit is reset.
BEEP
WORD 1
BIT 15
Command: Sound Instrument audible alarm.
Status:
Switches to 1 when command is executed, resets to 0 after the
command bit is reset.
DISPLAY MESSAGE
WORD 2
BIT 0
Command: Display message on Instrument display. Message loaded from display
memory 1 to 3 lines.
Status:
Switches to 1 when the command is received and the message is
displayed.
When scale operator operates any key, the message and bit are
cleared.
SCALE ABOVE MAXIMUM WEIGHT WORD
2 BIT 1
Command: Not applicable.
Status:
Bit is set when scale weight is at or above the programmed value.