beautypg.com

E. status/command word bit usage, continued – Fairbanks FB2550 SERIES User Manual

Page 170

background image

Section 9 Network Application Configuration

07/2012

170

51254 Rev. 3

E. STATUS/COMMAND WORD BIT USAGE, CONTINUED

SCALE ID

WORD 0

BITS 0,1,2

Command:

Changes Instrument display to applicable scale.

Status:

Value is the scale id if the scale is selected, from instrument
keyboard or fieldbus, else the value is zero.

MOTION

WORD 0

BIT 3

Command:

Not applicable.

Status:

Indicates that the scale senses motion.

OVER CAPACITY

WORD 0 BIT 4

Command: Not applicable.

Status:

Indicates that the scale is at 105% of capacity. If this condition is true
the gross weight is sent to the fieldbus as the scale capacity.

WITHIN 2% CAPACITY

WORD 0

BIT 5

Command: Not applicable.

Status:

Scale is within a range of +/- 2% of capacity and zero.

ENABLE TARE

WORD 0

BIT 6

Command: Enable keyboard tare or auto tare weight.

Status:

Tare weight enabled.

DISABLE TARE

WORD 0

BIT 7

Command: Disable keyboard tare and auto tare weight.

Status:

Tare weight disabled.

LB WEIGHT UNITS

WORD 0

BIT 8

Command: Switch scale to lb units.

Status:

Scale is indicating in lb units.