beautypg.com

Appendix i: fieldbus interface reference data, A. introduction, B. hardware specifications – Fairbanks FB2550 SERIES User Manual

Page 159

background image

07/2012

159

51254 Rev. 3

Appendix I: Fieldbus Interface Reference Data

A. INTRODUCTION

The Fieldbus interface(s) support a bi-directional communication capability for the
FB2550 instrument.

The FB2550 Interface supports a variety of industrial protocols.

– These include Profibus, DeviceNet, ControlNet and Modbus-RTU.

Even though the FB2550 can be configured with up to eight (8) scales, the
Fieldbus applications are limited to four (4) scales.

B. HARDWARE SPECIFICATIONS

Power

9-40 VDC (24 VDC Nominal)

Power Consumption

300 mA typical 800 mA max (@24 VDC)

Interface connections

Field bus as selected, serial channel

LEDs/indicators

Power, Network connection

Operating Temperature

0 to 70 C

Storage Temperature

-40 to 85 C

Operating humidity

90% non-condensing

Enclosure rating

None

Mounting options

Thru holes

Others

RoHS

Physical Dimensions

4.24 inches x 3.20 inches

Approval

CE