C. SOFTWARE SPECIFICATIONS, CONTINUED

INPUT

DATA FORMAT FROM GATEWAY, CONTINUED

STX character

1 byte,

(02h)

Command word 0

2 bytes,

(includes scale ID)

Command word 1

2 bytes,

Command word 2

2 bytes,

Setpoint 1 weight

6 characters,

Setpoint 2 weight

6 characters,

Tare Weight

6 characters,

Display Message 1

26 characters,

Display Message 2

26 characters,

Display Message 3

26 characters,

CRC

1 byte,

ETX character

1 byte

(03h)

NOTE WEIGHT VALUES

sent over the serial channel will represent data in the

field bus registers based on the settings of

bits 14

and

15

in

STATUS WORD 0

.

– If the data is set to be a 16 bit or 32 bit integer, then the integer value in the

register will be sent over the serial channel.

– If it is set to be 16 bit, the high order word will be ignored.

– If the data is set to be floating point, then the floating point value will be

multiplied by the scale factor and the integer portion of this resulting value will
be sent over the serial channel.

– In all cases if the resulting integer is greater than 999999, a value of

000000

will be sent over the Serial Channel.

– In all cases the scale must multiply the integer by the scale factor to determine

the actual weight.

Serial data is transferred according to the RS232 specification between the

gateway and the FB2550. The communications parameters are listed below.

Baud

115,200

Data Bits

8

Parity

None

Stop Bits

1