Method 2 - customizing data strings, continued – Fairbanks FB2550 SERIES User Manual
Page 100
Section 5: Input/ Output
07/2012
100
51254 Rev. 3
5.8.4. METHOD 2 - CUSTOMIZING DATA STRINGS,
CONTINUED
10. Touch the screen under
SCALE
to
select the scale where the data item is
obtained.
NOTE:
Selecting the Scale will limit the
available data for configuring data strings.
11. Touch the screen under
DATA
TYPE
to select a data item to edit.
There are many items available to select in
order to edit the particular data item selected.
Listed below are the available choices.
Text
– Allows text entry values in the location.
Units Tokens
– Designates the unit of the
data such as lbs or kgs.
Mode Tokens
– Designates if the weight is
Gross, Tare, or Net.
Scale Status
– Designates the operating
status of the scale such as motion, overcapacity,
and behind zero.
Load Cell Status
– Designates if a load cell has a potential problem.
Status Byte A, B
or
C
– Similar to Scale Status item but also includes graduation
size, decimal point, and units.
Gross Weight, Tare Weight, Net Weight
–Weights retrieved from the scale
selected for the data item configured.
Displayed Weigh
t – Value which is currently shown on the display.
<
- Removes the data item selected from the data string configuration.