Up to 110 mhz (4-terminal pair) lead components – Atec Agilent-16047A User Manual
Page 15
Up to 110 MHz (4-Terminal Pair)
Lead Components
10
16047A Test Fixture
Terminal Connector: 4-Terminal Pair, BNC
DUT Connection: 4-Terminal
Dimensions (approx.):
124 (W) x 31 (H) x 62 (D) mm
Weight (approx.): 205 g
Additional Error:
f: [MHz]
Description: This test fixture is designed for impedance
evaluation of axial/radial lead type devices.
The 16047A employs Kelvin contacts which realize a wide
impedance measurement range. The contact tip can be
changed according to the device shape.
Applicable Instruments: 4263B, 4268A, 4279A, 4284A,
4285A, 4288A, 4294A, (4192A, 4194A, 4263A, 4278A)*
* denotes the instrument is obsolete.
Frequency: DC to 13 MHz
Maximum Voltage: ±40 V peak max (AC+DC)
Operating Temperature: 0°C to 55°C
DUT Size: See figure with module sizes.
Furnished Accessories:
Each module size for the 16047A/D is shown above.
Option:
16047A-701: Add Shorting Plate
P/N 5000-4226
Compensation and Measurement: Select one of these
modules suitable for the DUT’s shape. Open and short
compensations are recommended before measurement.
Short compensation is performed by shorting the contacts
of the test fixture with a shorting plate. After performing
open and short compensations, the DUT is connected to
the test fixture.
16047A, 16047D module sizes
P/N 5000-4226
Shorting plate
Description
P/N
Qty.
Module For Axial Lead
16061-70022
2
Module For Radial Lead mounting on fixture
16061-70021
2
Module For Short Radial Lead
16047-65001
2
Operating Note
16047-90011
1
Type of Error
Impedance
Proportional Error
±5 x (f/10)
2
Material:
Brass (Ni-dipped)
Thickness:
1.0 mm
Residual impedance:
20nH, 1m
Ω