61

Command

ASCII (Telnet)
(Host to Processor)

Response
(Processor to Host)

Additional Description

Test Pattern
Set test pattern

X%

J

Tst

X%

]

Select test pattern

X%

. For

X%

:

0 = Off (none)
1 = Colorbars
2 = X-Hatch (16 x 12)
3 = 4 x 4 X-Hatch
4 = Grayscale
5 = Ramp
6 = Alt. Pixels
7 = White Field
8 = Crop
9 = Side-By-Side (4 x 3 crop)
10 = Quad Split (4 x 4)
11 = PIP Images (4 x 3 or 6 x 9

PIP columns)

12 = 1.78 Aspect (4 x 3/16 x 9)
13 = 1.85 Aspect (4 x 3/16 x 9)
14 = 2.35 Aspect (4 x 3/16 x 9).

NOTE: Test patterns 10 and

11 are not available on the
MGP 462 Pro models.

View test pattern

J

X%

]

View the currently selected test
pattern.

Executive Mode

NOTE: In all front panel lock modes, RS-232, RS-422, and Ethernet controls are not affected.

Disable executive mode

0 X

Exe 0

]

Unlock all front panel controls.

Enable executive mode

1 X

Exe 1

]

Lock front panel controls except
for the input buttons.

Enable executive mode 2

2 X

Exe 2

]

Lock all front panel controls.

View executive mode status

X

X3%

]

View executive mode status

X3%

. For

X3%

:

0 = Unlocked.
1 = Locked except for input

selection buttons.
2 = All controls are locked.

Special Functions
Output polarity

Example:

1 *

X3^

#

1 * 2 #

Pol

X3^

]

Pol 2

]

Set output polarity to

X3^

.

For

X3^

:

0 = H-/V- (default)
1 = H-/V+
2 = H+/V-
3 = H+/V+.
Output sync polarity is H+/V-.

View output polarity

1 #

X3^

]

View the current output polarity
setting

X3^

.