MGP Pro Series • Remote Configuration and Control
53
Command
ASCII (Telnet)
(Host to Processor)
Response
(Processor to Host)
Additional Description
Window Preset Effect
NOTE: You can select additional window preset transition effects using the MGP Series Control Program (see the control
software help file for more information).
Select effect
19 *
X2$
#
Wpe
X2$
]
Select window preset transition
effect
X2$
. For
X2$
:
0 = Cut
1 = Real time motion
View effect
19 #
X2$
]
View the current preset
transition effect.
Color
Specific value
X@
*
X*
C
X@
Col
X*
]
Set color level for window
X@
to
X*
.
X@
= 0-4. 0 = all windows.
X*
= picture adjustment range:
0-127. Default = 64.
Increment color value
X@
+ C
X@
Col
X*
]
Select the next higher color
level for window
X@
.
Decrement color value
X@
– C
X@
Col
X*
]
Select the next lower color level
for window
X@
.
View color level
X@
C
X*
]
View current color level setting
for window
X@
.
Tint
Specific value
X@
*
X*
T
X@
Tin
X*
]
Set the tint level for window
X@
to
X*
.
Increment tint value
X@
+ T
X@
Tin
X*
]
Select next higher tint level.
Decrement tint
value
X@
– T
X@
Tin
X*
]
Select next lower tint level.
View tint level
X@
T
X*
]
View current tint level setting.
Contrast
Specific value
X@
*
X*
^
X@
Con
X*
]
Set the contrast level for
window
X@
to
X*
.
Increment contrast
value
X@
+ ^
X@
Con
X*
]
Select next higher contrast
level.
Decrement contrast value
X@
– ^
X@
Con
X*
]
Select next lower contrast level.
View contrast level
X@
^
X*
]
View current contrast level
setting for window
X@
.
Brightness
Specific value
X@
*
X*
Y
X@
Brt
X*
]
Set the brightness level for
window
X@
to
X*
.
Increment brightness value
X@
+ Y
X@
Brt
X*
]
Select next higher brightness
level.
Decrement brightness value
X@
– Y
X@
Brt
X*
]
Select next lower brightness
level.
View brightness level
X@
Y
X*
]
View current brightness level
setting.