beautypg.com

Auto-image, Threshold value, D auto-image sis command (see the – Extron Electronics IN1608 MA User Guide User Manual

Page 46: Sis command, Commands (see, Auto-image threshold value

background image

IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control

40

Command

ASCII Command

(host to scaler)

Response

(scaler to host)

Additional Description

Auto-Image

Enable

X!

*1A

Img

X!

*1

]

Activate Auto-Image for input

X!

.

Disable

X!

*0A

Img

X!

*0

]

Turn off Auto-Image for input

X!

.

View

X!

A

X(]

View the Auto-Image setting for
input

X!

.

Execute

A

Img0

]

Execute an Auto-Image for the
current input (follows the aspect
ratio of the current input).

Execute and fill

1*A

Img1

]

Execute an Auto-Image and fill the
entire output.

Execute and follow

2*A

Img2

]

Execute an Auto-Image and
maintain the aspect ratio of the
current input.

Auto-Image threshold value (luminosity value which the scaler defines as active video for Auto-Image)

Set value

EX2(

ALVL

}

Alvl

X2(]

Set the global Auto-Image
luminosity to

X2(

.

View

E

ALVL

}

X2(]

View the global Auto-Image
luminosity setting.

Horizontal start

Specify a value

EX$

HSRT

}

Hsrt

X!

*

X$]

Set the horizontal start position.

Increment value

E

+HSRT

}

Hsrt

X!

*

X$]

Increase the horizontal start
position.

Decrement value

E

-HSRT

}

Hsrt

X!

*

X$]

Decrease the horizontal start
position.

View

E

HSRT

}

X$]

View the horizontal start position.

Vertical start

Specify a value

EX$

VSRT

}

Vsrt

X!

*

X$]

Set the vertical start position.

Increment value

E

+VSRT

}

Vsrt

X!

*

X$]

Increase the vertical start position.

Decrement value

E

-VSRT

}

Vsrt

X!

*

X$]

Decrease the vertical start
position.

View

E

VSRT

}

X$]

View the vertical start position.

NOTES:

X!

= Input selection

1-6

(IN1606) or

1-8

(IN1608 models)

X$

= H/V start

0-255

X(

= Enable or disable

0

= off or disabled

1

= on or enabled

X2(

= Auto-Image threshold value

0-100

(where

0

= black and

100

= white;

25

= default)

This manual is related to the following products: