IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control
31
SIS Configuration and
Control
The scaler can be configured and controlled with Extron Simple Instruction Set (SIS)
commands when connected to a host computer or other device (such as a control system).
Attach the host device to the rear panel RS-232 connector, the LAN port, or the front
panel USB port. Commands can be entered using a Telnet application such as the Extron
DataViewer, available at
(see the DataViewer Help file for more details).
This section describes SIS communication and control. Topics in this section include:
•
•
•
The scaler uses a protocol of 9600 baud, 1 stop bit, no parity, and no flow control (see
on page 11).
Host and Scaler Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the scaler determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the scaler to the host end with a carriage return and a line feed (CR/LF =
]
),
indicating the end of the response character string (one or more characters).
Scaler-Initiated Messages
When a local event such as a front panel selection or adjustment takes place, the scaler
responds by sending a message to the host. No response is required from the host. Example
scaler-initiated messages are listed here.
•
In
X!
All
]
(where
X!
is the input number during an input switch).
•
Reconfig
]
The scaler sends this response when an input is switched or when a new
signal is detected.
•
HplgO
X@]
The scaler sends this response when a hot plug event on output
X@
is
detected.
Copyright Information
The copyright message is displayed upon connecting to a scaler via TCP/IP or Telnet or after
a power cycle via RS-232 and depends on the scaler model.
]
© Copyright YYYY, Extron Electronics, IN1606, Vx.xx, 60-1081-01
]
Ddd, DD MMM YYYY HH:MM:SS
]
(day, date, and time as in
Fri, 17 Feb 2013 11:27:33
)
]
© Copyright YYYY, Extron Electronics, IN1608, Vx.xx, 60-1238-01
]
Ddd, DD MMM YYYY HH:MM:SS
]
(day, date, and time as in
Fri, 17 Feb 2013 11:27:33
)
]
© Copyright YYYY, Extron Electronics, IN1608 SA, Vx.xx, 60-1238-02
]
Ddd, DD MMM YYYY HH:MM:SS
]
(day, date, and time as in
Fri, 17 Feb 2013 11:27:33
)
]
© Copyright YYYY, Extron Electronics, IN1608 MA, Vx.xx, 60-1238-03
]
Ddd, DD MMM YYYY HH:MM:SS
]
(day, date, and time as in
Fri, 17 Feb 2013 11:27:33
)
Vx.xx
is the firmware version number.