Reset modes – Extron Electronics IN1608 MA User Guide User Manual
Page 36
IN1606 and IN1608 Series Scaling Presentation Switcher • Operation
30
Reset Modes
There are three reset modes (numbered 1, 4, and 5). These are available by pressing the
recessed Reset button on the rear panel (see the following table for a summary of the reset
modes).
ATTENTION: Review the reset modes carefully. Using the wrong reset mode may result
in unintended loss of flash memory programming, port reassignment, or processor
reboot.
NOTE: The reset modes listed close all open IP and Telnet connections and all sockets.
Each mode is a separate function, not a continuation from mode 1 to mode 5.
Reset Mode Summary
Mode
Activation
Result
Purpose/Notes
Use Factory Firmwar
e
1
Hold in the recessed Reset button for
30 seconds while applying power to the
scaler.
NOTE: After a mode 1 reset,
update the device with the latest
firmware version.
DO NOT
operate with the firmware version
that results from this mode reset.
This temporarily resets the device
to factory default until power is
recycled. To use factory default
firmware, upload that version
again.
The device reverts to the factory default
firmware.
•
Firmware reverts to the factory default for a
single power cycle.
•
All user files and settings (drivers, audio
and video adjustments, IP settings, and so
on) are maintained.
NOTE: If you do not want to update the
firmware or perform a mode 1 reset by
mistake, cycle power to the device to
return to the firmware version running
prior to the reset.
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Reset IP
Settings
4
Hold down the Reset button for
approximately 6 seconds until the Reset
LED blinks twice. Then press Reset
momentarily (<1 second).
IP settings revert to factory defaults.
•
Port mapping reverts to factory default.
•
DHCP turns off.
•
IP address is set to 192.168.254.254.
•
Reset LED blinks four times in quick
succession during reset.
Use mode 4 to reset
all IP settings back to
factory defaults.
Reset to Factory Default
5
Hold down the Reset button for
approximately 9 seconds until the Power
LED blinks 3 times. Then press Reset
momentarily (<1 second).
The device reverts to the factory defaults
except for firmware.
•
Mode 4 results are performed.
•
All user modifiable configurations reset to
default values including IP settings and
real-time adjustments.
•
All user loaded files are deleted.
•
The Reset LED blinks 4 times in quick
succession during the reset.
Use mode 5 to
restart with default
configuration. This
is equivalent to SIS
command ZQQQ.