beautypg.com

Command and response tables, Input switching commands – Extron Electronics IN1608 MA User Guide User Manual

Page 44

background image

IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control

38

Command and Response Tables

Command

ASCII Command

(host to scaler)

Response

(scaler to host)

Additional Description

Input Switching Commands

Input selection

Video and audio

X!

!

In

X!•

All

]

Select video and audio from
input

X!

.

Video only

X!

&

In

X!•

RGB

]

Select video-only from input

X!

.

Audio only

X!

$

In

X!•

Aud

]

Select audio-only from input

X!

.

View video input

&

X!]

View the current video input.

View audio input

$

X!]

View the current audio input.

View current input

!

X!]

View the current video and
audio input.

NOTE: Audio breakaway (

$

) is not allowed to an input configured for any digital audio format.

Video breakaway (

&

) is not allowed from an input configured for any digital audio format.

Attempting either of these invalid modes gives an

E17

error.

Audio breakaway is always allowed back to the current video input.

Auto switch mode

Disable auto switch
mode

E

0AUSW

}

Ausw0

]

Manual input switching only

Prioritize highest active
input

E

1AUSW

}

Ausw1

]

Automatically switches to the
highest numbered active input.

Prioritize lowest active
input

E

2AUSW

}

Ausw2

]

Automatically switches to the
lowest numbered active input.

View auto switch
mode

E

AUSW

}

X5$]

View the current auto switch
mode.

NOTES:

X!

= Input selection

1-6

(IN1606) or

1-8

(IN1608 models)

X5$

= Auto switch mode

0

= disable

1

= gives priority to the highest numbered active input

2

= gives priority to the lowest numbered active input

This manual is related to the following products: