IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control
38
Command and Response Tables
Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Input Switching Commands
Input selection
Video and audio
X!
!
In
X!•
All
]
Select video and audio from
input
X!
.
Video only
X!
&
In
X!•
RGB
]
Select video-only from input
X!
.
Audio only
X!
$
In
X!•
Aud
]
Select audio-only from input
X!
.
View video input
&
X!]
View the current video input.
View audio input
$
X!]
View the current audio input.
View current input
!
X!]
View the current video and
audio input.
NOTE: Audio breakaway (
$
) is not allowed to an input configured for any digital audio format.
Video breakaway (
&
) is not allowed from an input configured for any digital audio format.
Attempting either of these invalid modes gives an
E17
error.
Audio breakaway is always allowed back to the current video input.
Auto switch mode
Disable auto switch
mode
E
0AUSW
}
Ausw0
]
Manual input switching only
Prioritize highest active
input
E
1AUSW
}
Ausw1
]
Automatically switches to the
highest numbered active input.
Prioritize lowest active
input
E
2AUSW
}
Ausw2
]
Automatically switches to the
lowest numbered active input.
View auto switch
mode
E
AUSW
}
X5$]
View the current auto switch
mode.
NOTES:
X!
= Input selection
1-6
(IN1606) or
1-8
(IN1608 models)
X5$
= Auto switch mode
0
= disable
1
= gives priority to the highest numbered active input
2