Extron Electronics IN1608 MA User Guide User Manual
Page 42
IN1606 and IN1608 Series Scaling Presentation Switcher • SIS Configuration and Control
36
X5!
= Increment value
dB value multiplied by ten, in 0.1 dB increments, to
raise or lower a group fader (for example,
100 = 10 dB)
X5@
= Password
12 digits and alphanumeric characters for user or
admin passwords.
NOTE:
/ \ | * and space are invalid characters.
X5#
= Verbose mode
0 = clear or none (default for Telnet connections)
1 = verbose mode (default for RS-232)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
X5$
= Auto switch mode
0 = disable
1 = prioritizes the highest numbered active input
2 = prioritizes the lowest numbered active input
X5%
= Video mute on all outputs
0 = all outputs are unmuted
1 = at least one output is muted
2 = at least one output is muted and sync is
disabled
X5^
= Volume knob group number
1 = program volume
3 = mic volume
8 = output volume (default)
X5&
=
Gain or mute control
40100
= mic 1 (mix volume only)
40000
= mic 1 (mute only)
40101
= mic 2 (mix volume only)
40001
= mic 2 (mute only)
60000
= output 1
60002
= output 2
60004
= variable output L
60005
= variable output R
60006
= digital output L
60007
= digital output R
60008
= amplified output L (IN1608 SA only) or
amplified output (IN1608 MA only)
60009
= amplified output R (IN1608 SA only)
X5*
=
Gain or trim level
-1000 to 0 = dB value multiplied by ten, in 0.1 dB
increments, (for example, -100 = -10 dB)
0 = default