H-5223 – Xylem H-5223 User Manual
Page 99

Command:
GOESSTCOLUMNnSHEFCODE=XX
Description:
Set the SHEF code for the n
th
column of self timed GOES data.
Parameters:
‘n’ ranges from 1-20.
Response:
None.
Example:
-> GOESSTCOLUMN3SHEFCODE=DT
5
Command sent to the XL™.
rs
Response from the XL™.
Command:
GOESRRCHANNEL?
Description:
Read the channel to be used for GOES random transmissions.
Parameters:
None.
Response:
An ASCII text string is returned with the channel.
Example:
-> GOESRRCHANNEL?
5
Command sent to the XL™.
GOES RR CHANNEL = 123
rs
Response sent to the host system.
Command:
GOESRRCHANNEL=XXX
Description:
Set the channel for random transmissions of the GOES radio.
Parameters:
The channel is a 3 character decimal value, ranging from 000-200.
Response:
None.
Example:
-> GOESRRCHANNEL=111
5
Command sent to the XL™.
rs
Response sent to the host system.
Command:
GOESRRRATE?
Description:
Read the random transmission rate. This determines the window during which the
GOES radio will transmit after detecting a random trigger.
Parameters:
None.
Response:
An ASCII text string is returned in the format of hh:mm:ss.
C-40 Remote Operation (Command Mode)