H-5223 – Xylem H-5223 User Manual
Page 100

Example:
-> GOESRRRATE?
5
Command sent to the XL™.
GOES RR Rate = 00:00:30
rs
Response sent to the host system.
Command:
GOESRRRATE=hh:mm:ss
Description:
Set the transmission rate for the random report mode of the GOES radio.
Parameters:
The new rate is to be entered in the format of HH:MM:SS, where H is hours, M is
minutes, and S is seconds.
Response:
None.
Example:
-> GOESRRRATE=00:01:00
5
Command sent to the XL™.
rs
Response sent to the host system.
Command:
GOESRRTRIGGERMODE?
Description:
Read the current mode of random report operation of the GOES radio. This value,
along with trigger source, determines what conditions are checked when evaluating
whether or not to generate a GOES random report.
Parameters:
None.
Response:
An ASCII text string is returned. The response will be “Always ”, “> Set Pt”, “<
Set Pt”, or “Delta “. (See GOES section for details)
Example:
-> GOESRRTRIGGERMODE?
5
Command sent to XL™.
GOES RR Trigger Mode = Always
rs
Response from XL™.
Command:
GOESRRTRIGGERMODE=XXXXXX
Description:
Set the current mode of GOES radio random report operation.
Parameters:
The flag can be set to “Always ”, “> Set Pt”, “< Set Pt”, or “Delta “.
Response:
None.
Example:
-> GOESRRTRIGGERMODE=> Set Pt
5
Command sent to
XL™.
rs
Response from XL™.
H-5223
Remote Operation (Command Mode) C-41