H-5223 – Xylem H-5223 User Manual
Page 102

Description:
Set the RR trigger point.
Parameters:
The XL™ accepts a real number represented in ASCII text format.
Response:
None.
Example:
-> GOESRRTRIGGERPOINT=3.3
5
Command sent to XL™.
rs
Response from XL™.
Command:
GOESRRFORCEXMIT?
Description:
Immediately forces a GOES random report transmission.
Parameters:
None.
Response:
None
Example:
-> GOESRRFORCEXMIT
5
Command sent to the XL™.
rs
Response from XL™.
Command:
GOESRRBUFFERCOUNT?
Description:
Counts the number of bytes currently in the GOES random report buffer.
Parameters:
None.
Response:
An ascii text string is returned with an integer number representing the buffer count
Example:
-> GOESRRBUFFERCOUNT?
5
Command sent to the XL™.
GOES RR Buffer Count = 232
rs
Response from XL™.
Command:
GOESRRCOLUMNnSOURCE?
Description:
Read the source of the n
th
column of data to be sent in the GOES random report
transmission.
Parameters:
‘n’ can range from 1-5, indicating the corresponding column.
Response:
The source of the column corresponding to ‘n’ (e.g. Stage, PSI, Temp).
Example:
-> GOESRRCOLUMN2SOURCE?
5
Command sent to XL™.
H-5223