beautypg.com

H-5223 – Xylem H-5223 User Manual

Page 102

background image

Description:

Set the RR trigger point.

Parameters:

The XL™ accepts a real number represented in ASCII text format.

Response:

None.

Example:

-> GOESRRTRIGGERPOINT=3.3

5

Command sent to XL™.

rs

Response from XL™.

Command:

GOESRRFORCEXMIT?

Description:

Immediately forces a GOES random report transmission.

Parameters:

None.

Response:

None

Example:

-> GOESRRFORCEXMIT

5

Command sent to the XL™.

rs

Response from XL™.

Command:

GOESRRBUFFERCOUNT?

Description:

Counts the number of bytes currently in the GOES random report buffer.

Parameters:

None.

Response:

An ascii text string is returned with an integer number representing the buffer count

Example:

-> GOESRRBUFFERCOUNT?

5

Command sent to the XL™.

GOES RR Buffer Count = 232

rs

Response from XL™.

Command:

GOESRRCOLUMNnSOURCE?

Description:

Read the source of the n

th

column of data to be sent in the GOES random report

transmission.

Parameters:

‘n’ can range from 1-5, indicating the corresponding column.

Response:

The source of the column corresponding to ‘n’ (e.g. Stage, PSI, Temp).

Example:

-> GOESRRCOLUMN2SOURCE?

5

Command sent to XL™.

H-5223