H-5223 – Xylem H-5223 User Manual
Page 65

GOES COMMANDS
GOESMODE?/=
Off, Timed, Random, Both
GOESADDRESS?/=
8 character address, assigned by NESDIS
GOESTIME?/=
International standard time
GOESSTCHANNEL?/=
Self timed channel number
GOESSTRATE?/=
Self Timed transmit rate
GOESSTOFFSET?/=
Offset from midnight to first transmit
GOESSTFORMAT?/=
Format of Self Timed data (SHEF, binary, etc.)
GOESSTORDER?/=
Order of Self Timed data
GOESSTSENDSHEFCODES?/=
Send SHEF codes with each transmit (yes, no)
GOESSTAPPENDBATTERY?/=
Send 1 battery reading at end of transmission
GOESSTSCANSPERXMIT?/=
# of scans per transmission
GOESSTBUFFERCOUNT?/=
# of bytes in transmit buffer
GOESSTCOLUMN1-20SOURCE?/=
Source of ST output column
GOESSTCOLUMN1-20SHEFCODE?/=
SHEF code of ST output column
GOESSTCOLUMN1-20SKIPRATE?/=
Skip rate of ST output column
GOESRRCHANNEL?/=
Random Report channel number
GOESRRRATE?/=
Random Report transmit rate
GOESRRTRIGGERMODE?/=
Trigger mode (always, delta, ...)
GOESRRTRIGGERSOURCE?/=
Trigger source
GOESRRTRIGGERPOINT?/=
Trigger point
GOESRRFORCEXMIT
Force a random transmission
GOESRRBUFFERCOUNT?
# of bytes in RR transmit buffer
GOESRRCOLUMN1-5SOURCE?/=
Source of RR output column
C-6 Remote Operation (Command Mode)
H-5223