H-5223 – Xylem H-5223 User Manual
Page 25

V - View status:
Displays system status information.
I - Sensor Input Setup: Used to configure the sensor input parameters.
D - Data Options:
Allows the user to retrieve data from the unit, and check other data
file statistics.
O - Output Options:
Defines how the data is stored, transmitted or displayed.
S - Scan Setup:
Defines when and how often the unit scans the sensors.
C - Configure System:
Sets basic system options such as time and date.
X - Exit:
Exits the H-5223 Menu mode, and returns to low power mode.
3.4 V - View Status
The following shows what the “View Status Submenu” screen looks like. This screen allows the
user to view the current status of basic setup options and measurements. Options cannot be
changed in this menu.
--- View Status ---
Site ID: Site_ID
Time: HH:MM:SS
Date: MM/DD/YY
Scanning: Off
Next Scan: HH:MM:SS
GOES Mode: Off
M - More
Enter Option >
--- View Status ---
Battery: 12.8
Batt Max: 13.5
Batt Min: 12.6
System Resets: 001
Version: 1.00
R - Reset Batt & Resets
Enter Option >
Site ID:
This displays the system Site ID. The site ID is also the name used for the data files.
Time:
This is a status screen that shows the current time. There is no option here to change the
time. To change the time use the ‘Configure System’ menu.
H-5223
Remote Operation (Menu Mode) 3-3