H-5223 – Xylem H-5223 User Manual
Page 96

Response:
None.
Example:
-> GOESSTORDER=CHANNEL
5
Command sent to the XL™.
rs
Response sent to the host system.
Command:
GOESSTSENDSHEFCODES?
Description:
Read the send SHEF codes flag. If this is set to “YES”, each self timed GOES
transmission will include SHEF code column headers.
Parameters:
None.
Response:
An ASCII text string is returned consisting of either “Yes” or “No “.
Example:
-> GOESSTSENDSHEFCODES?
5
Command to XL™.
GOES ST Send SHEF Codes = No
rs
Response from XL™.
Command:
GOESSTSENDSHEFCODES=XXX
Description:
Set the flag to send SHEF codes with each self-timed transmission.
Parameters:
The flag can be set to either “Yes” or “No “.
Response:
None.
Example:
-> GOESSTSENDSHEFCODES=NO
5
Command sent to the XL™.
rs
Response from the XL™.
Command:
GOESSTAPPENDBATTERY?
Description:
Read the append battery flag. If this flag is set, a battery reading will be appended
to each GOES self-timed transmission.
Parameters:
None.
Response:
An ASCII text string is returned indicating whether or not the XL™ will append a
battery reading when transmitting data. The response is either “Yes” or “No “.
Example:
-> GOESSTAPPENDBATTERY?
5
Command sent to the XL™.
GOES ST Append Battery = Yes
rs
Response from the XL™.
H-5223