Web-Based Management


Local Time Zone

Conversion from UTC

Time at 12:00 UTC

ZP5 - USSR Zone 4

+5 hours

5 pm

ZP6 - USSR Zone 5

+6 hours

6 pm

WAST - West Australian Standard

+7 hours

7 pm

CCT - China Coast, USSR Zone 7

+8 hours

8 pm

JST - Japan Standard, USSR Zone 8

+9 hours

9 pm

EAST - East Australian Standard GST

Guam Standard, USSR Zone 9

+10 hours

10 pm

IDLE - International Date Line

NZST - New Zealand Standard

+12 hours

Midnight

SNTP Sever URL: Set the SNTP server IP address. You can assign a local network

time server IP address or an internet time server IP address.

Switch Timer: When the switch has successfully connected to the SNTP server whose

IP address was assigned in the column field of SNTP Server URL, the current

coordinated time is displayed here.

Daylight Saving Period: Set up the Daylight Saving beginning date/time and Daylight

Saving ending date/time. Please key in the value in the format of ‗YYYYMMDD‘ and

‗HH:MM‘ (leave a space between ‗YYYYMMDD‘ and ‗HH:MM‘).

YYYYMMDD: an eight-digit year/month/day specification.

HH:MM: a five-digit (including a colon mark) hour/minute specification.

For example, key in ‗20070701 02:00‘ and ‗20071104 02:04‘ in the two column fields

respectively to represent that DST begins at 2:00 a.m. on March 11, 2007 and ends at

2:00 a.m. on November 4, 2007.

Daylight Saving Offset (mins): For non-US and European countries, specify the

amount of time for day light savings. Please key in the valid figure in the range of

minute between 0 and 720, which means you can set the offset up to 12 hours.