Web-Based Management

6.8 System Event Log


This page allows the user to decide whether to send the system event log, and select the mode

which the system event log will be sent to client only, server only, or both client and server.

What kind of event log will be issued to the client/server depends on the selection on the Event

Configuration tab. There are five types of event—Device Cold Start, Device Warm Start,

Authentication Failure, X-Ring Topology Change, and Port Event—available to be issued as

the event log.

6.8.1 Syslog Configuration


Syslog Client Mode: Select the system log mode—Client Only, Server Only, or Both.

‗Client Only‘ means the system event log will only be sent to this interface of the switch,

but on the other hand ‗Server Only‘ means the system log will only be sent to the remote

system log server with its IP assigned. If the mode is set in ‗Both‘, the system event log will

be sent to the remote server and this interface.

System Log Server IP Address: When the ‗Syslog Mode‘ item is set as Server Only/Both,

the user has to assign the system log server IP address to which the log will be sent.

 Click

Reload

to refresh the event log displaying area.

 Click

Clear

to clear all the current event logs.

 Make sure the selected mode is correct, and click

Apply

to have the setting take effect.