beautypg.com

Receive g.703 section 10 synchronization signal, Monitor mode, Liu transmitter – Rainbow Electronics DS26504 User Manual

Page 81: Liu t, Ransmitter, Figure 13-2. typical monitor application, 3 liu transmitter

background image

DS26504 T1/E1/J1/64KCC BITS Element

81 of 128

13.2.2 Receive G.703 Section 10 Synchronization Signal
The DS26504 can receive a 2.048MHz square-wave synchronization clock as specified in Section 10 of
ITU G.703. To use the DS26504 in this mode, set the mode configuration bits in the Mode Configuration
Register (MCREG).

13.2.3 Monitor Mode
Monitor applications in both E1 and T1 require various flat-gain settings for the receive-side circuitry.
The DS26504 can be programmed to support these applications via the monitor mode control bits MM1
and MM0 in the LIC3 register.


Figure 13-2. Typical Monitor Application
















13.3 LIU Transmitter

The DS26504 uses a phase-lock loop along with a precision digital-to-analog converter (DAC) to create
the waveforms that are transmitted onto the E1 or T1 line. The waveforms created by the DS26504 meet
the latest ETSI, ITU, ANSI, and AT&T specifications. The waveform that is to be generated is set by the
transmit mode bits (TMODE[3:0]) in the MCREG register, as well as the L2/L1/L0 bits in register LIC1
if applicable.

ITU specification G.703 requires an accuracy of ±50ppm for both T1 and E1. TR62411 and ANSI specs
require an accuracy of ±32ppm for T1 interfaces. The transmit clock can be sourced from the recovered
clock (RCLK), the pre-scaled MCLK, the TCLK pin, or the TX PLL. See the TX PLL clock mux
diagram in

Figure 3-3

. Due to the nature of the design of the transmitter in the DS26504, very little jitter

(less than 0.005UI

P-P

broadband from 10Hz to 100kHz) is added to the jitter present on the selected

transmit clock source. Also, the waveforms created are independent of the duty cycle of TCLK. The
transmitter in the DS26504 couples to the transmit twisted pair (or coaxial cable in some applications) via
a 1:2 step-up transformer. For the device to create the proper waveforms, the transformer used must meet
the specifications listed in

Table 13-1

. The DS26504 has the option of using software-selectable transmit

termination.

PRIMARY
T1/E1 TERMINATING
DEVICE

MONITOR
PORT JACK

T1/E1 LINE

X
F
M
R

DS26504

Rt

Rm

Rm

SECONDARY T1/E1
TERMINATING