20. AC TIMING PARAMETERS AND DIAGRAMS

Capacitive test loads are 40pF for bus signals and 20pF for all others.

20.1 Multiplexed Bus

Table 20-1. AC Characteristics, Multiplexed Parallel Port

(V

DD

= 3.3V

±5%, T

A

= 0°C to +70°C for DS26504L; V

DD

= 3.3V

±5%, T

A

= -40°C to +85°C for

DS26504LN.) (Note 1) (

Figure 20-1

,

Figure 20-2

, and

Figure 20-3

)

PARAMETER SYMBOL

MIN

TYP

MAX

UNITS

NOTES

Cycle Time

t

CYC

200 ns

Pulse Width,

DS Low or RD High

PW

EL

100

ns

Pulse Width,

DS High or RD Low

PW

EH

100

ns

Input Rise/Fall Times

t

R

, t

F

20 ns

R/

W Hold Time

t

RWH

10 ns

R/

W Setup Time Before DS High

t

RWS

50 ns

CS Setup Time Before DS, WR, or
RD Active

t

CS

20 ns

CS Hold Time

t

CH

0 ns

Read Data Hold Time

t

DHR

10 50 ns

Write Data Hold Time

t

DHW

5 ns

Muxed Address Valid to AS or
ALE Fall

t

ASL

15 ns

Muxed Address Hold Time

t

AHL

10 ns

Delay Time

DS, WR, or RD to AS

or ALE Rise

t

ASD

20 ns

Pulse Width AS or ALE High

PW

ASH

30

ns

Delay Time, AS or ALE to

DS,

WR, or RD

t

ASED

10 ns

Output Data Delay Time from

DS

or

RD

t

DDR

80 ns

Data Setup Time

t

DSW

50 ns

Note 1:

The timing parameters in this table are guaranteed by design (GBD).