Ac timing parameters and diagrams, Multiplexed bus, Ultiplexed – Rainbow Electronics DS26504 User Manual
Page 115: 1 multiplexed bus
DS26504 T1/E1/J1/64KCC BITS Element
115 of 128
20. AC TIMING PARAMETERS AND DIAGRAMS
Capacitive test loads are 40pF for bus signals and 20pF for all others.
20.1 Multiplexed Bus
Table 20-1. AC Characteristics, Multiplexed Parallel Port
(V
DD
= 3.3V
±5%, T
A
= 0°C to +70°C for DS26504L; V
DD
= 3.3V
±5%, T
A
= -40°C to +85°C for
DS26504LN.) (Note 1) (
PARAMETER SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Cycle Time
t
CYC
200 ns
Pulse Width,
DS Low or RD High
PW
EL
100
ns
Pulse Width,
DS High or RD Low
PW
EH
100
ns
Input Rise/Fall Times
t
R
, t
F
20 ns
R/
W Hold Time
t
RWH
10 ns
R/
W Setup Time Before DS High
t
RWS
50 ns
CS Setup Time Before DS, WR, or
RD Active
t
CS
20 ns
CS Hold Time
t
CH
0 ns
Read Data Hold Time
t
DHR
10 50 ns
Write Data Hold Time
t
DHW
5 ns
Muxed Address Valid to AS or
ALE Fall
t
ASL
15 ns
Muxed Address Hold Time
t
AHL
10 ns
Delay Time
DS, WR, or RD to AS
or ALE Rise
t
ASD
20 ns
Pulse Width AS or ALE High
PW
ASH
30
ns
Delay Time, AS or ALE to
DS,
WR, or RD
t
ASED
10 ns
Output Data Delay Time from
DS
or
RD
t
DDR
80 ns
Data Setup Time
t
DSW
50 ns
Note 1:
The timing parameters in this table are guaranteed by design (GBD).