11. T1 SYNCHRONIZATION STATUS MESSAGE

The DS26504 has a BOC controller to handle SSM services in T1 mode.

Table 11-1. T1 SSM Messages

QUALITY

LEVEL

DESCRIPTION BOC

CODE

1

Stratum 1 Traceable

0000010011111111

2

Synchronized Traceablity Unknown

0000100011111111

3

Stratum 2 Traceable

0000110011111111

4

Stratum 3 Traceable

0001000011111111

5

SONET Minimum Clock Traceable

0010001011111111

6

Stratum 4 Traceable

0010100011111111

7

Do Not Use for Synchronization

0011000011111111

User Assignable

Reserved for Network Synchronization Use

0100000011111111


11.1 T1 Bit-Oriented Code (BOC) Controller

The DS26504 contains a BOC generator on the transmit side and a BOC detector on the receive side. The
BOC function is available only in T1 mode. In typical BITS applications, the BOC controller would be
used to transmit and receive Synchronization Status Messages in T1 mode over the data link.

11.2 Transmit BOC

Bits 0 through 5 in the TFDL register contain the BOC or synchronization status message to be
transmitted. Setting BOCC.0 = 1 causes the transmit BOC controller to immediately begin inserting the
BOC sequence into the FDL bit position. The transmit BOC controller automatically provides the abort
sequence. BOC messages will be transmitted as long as BOCC.0 is set. TFSE (T1TCR2.6) must be set =
0 when using the transmit BOC function.

To transmit a BOC, use the following:

1) Write 6-bit code into the TFDL register.
2) Set SBOC bit in BOCC register = 1.