Safety cage extensions – Grain Systems PNEG-707GSI User Manual
Page 92

7. Outside Ladder
92
PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer
Safety Cage Extensions
Install safety cage extensions from top safety cage to bell safety cage just above foundation as follows.
Quantity depends upon dryer model.
1. Splice outside ladder stiffeners with ladder stiffener splices. Snug bolt outside ladder stiffeners
behind 44" formed ladder sections. Install safety cage brackets and safety cage hoops like top
safety cage.
2. Before lifting each section, tighten bolts in outside ladder with safety cage for that section.
As dryer is constructed, continue installing safety cage extensions to each section of dryer before
lifting it.
Figure 7L Close Up - Pointing to ladder
stiffener slice. Install ladder stiffener
splice with 4 bolts (circle).
Figure 7M Outside ladder bracket bolts
through 44" formed ladder sections
and outside ladder stiffener.
Figure 7N Close Up - Outside Ladder Brackets
Figure 7O As dryer is constructed, continue
installing outside ladder with safety cage.