beautypg.com

Grain Systems QSG-001 User Manual

Controls, Default operation screen, Configuration buttons

background image

1

2

3

4

5

Default Operation Screen

The Default Operation Screen is divided into five (5) sections:

1. Dryer Operation Animation: Located on the left side of the screen, this shows the status

of the fans/heaters, load and unload augers and meter rolls. It will also display the grain

temperature, moisture content, moisture control setpoint and the bushel counter.

2. Dryer Status: Located at the very top of the right side, the dryer status will tell the user if the

dryer is stopped, started, loading or unloading.

3. Dryer Status Chart: This chart, located directly under dryer status, will show the grain

temperature, moisture in/out, temperature out and meter roll output (M.R.O) over a

period of time.

4. Plenum(s): Located directly below the dryer status chart, the plenum section will show

temperature setpoint, actual plenum temperature and burner status.

5. Configuration buttons: Select from Timers, Temp, Setup, View and M/C buttons.

Configuration Buttons

Use the following buttons to access these system settings:

Select this button to modify Load Delay, Out of Grain (OOG) Timer, Fan

Delay, Unload Delay, and Cool Down.

Select this button to modify the Plenum Temperature Setpoint and the

Grain Temperature Setpoint.

Select this button to modify Drying Mode, Moisture Control Setup,

Unload Parameters, Plenum Temp Manager, Burner Mode, Calibrate

Moisture Sensor, and the Extended Setup Screen.

Select this button to see the Table View, Graph View, Owner’s Manual,

Error History, System Information and Software Version Info.

Select this button to access Modifying Temperature Setpoint and

Modifying Moisture Setpoint.

Located within the Setup Screen, selecting this button

allows you to modify Diagnostics, Differential, Printer

Setup, Meter Roll Reverse, BPH Calibration, Set Time/

Date, Temp Scale, Dryer Model, Data Logger Setup,

User Saved Defaults and Batches.

Note: Screen shot of 1100 Series Dryer.

Screens are similar but may vary slightly

depending on model.

1

2

3

4

5

QSG-001

PERSOnAL EqUIPMEnT RECORD
Model Number:
Dryer Serial Number:
Number of Modules/Fans/Heaters:
Fuel/Length:
Electrical Phase/Voltage:

ContRolS

5 SPEED

AUTO

HI 575

RPM 9.9
BPH 1610
TB 3439

130 °F

17.0%

- ExITInG GRAIn MOISTURE

- ExITInG GRAIn TEMPERATURE

- CURREnT MOISTURE COnTROL

- CURREnT METER ROLL SPEED
- METER ROLL RPM
- BUSHELS PER HOUR
- TOTAL BUSHELS

- UnLOAD SwITCH POSITIOn

The GSI Group, LLC • 1004 East Illinois Street • Assumption, IL 62510

QSG-001

notICE: PRIoR to oPERAtIon, READ tHE

oWnERS MAnUAl FoR IMPoRtAnt SAFEtY

InStRUCtIonS AnD FUll EQUIPMEnt DEtAIlS

QSG-001 April/11

Copyright ©2011 by The GSI Group, LLC | Printed in the USA | Due to continual improvements, The GSI Group LLC reserves the right to change designs and specifications without notice.

Suggested Initial Settings Check

NOTE: Default settings work well in most cases.

1. Power on using the Control Power switch and wait 30 seconds.
2. Now viewing the “Boot Screen”, select “Start Dryer”.
3. Setup timers.
4. Using the “Setup” screen, select the following options to configure the dryer.

a.)

Select drying mode settings.

b.)

Check unload parameter settings

c.)

Select moisture control settings.

d.)

Check burner mode settings.

5. Using the “Extended Setup Screen”, select the following options to configure the dryer.

a.)

Check data logger settings.

b.)

Check date and time settings

c.)

Check temp scale settings.