Divider hopper – Grain Systems PNEG-707GSI User Manual
Page 171

15. Fans, Divider Hopper, Reducer Walkway
PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer
171
Divider Hopper
Divider hopper is formed by joining inner divider hopper sections and outer divider hopper sections in a
“V” shape.
Divider hopper encircles fan cluster.
Divider hopper divides heat section from cool section.
Divider hopper fits between fan skirting and inner wall of dryer.
For divider hopper placement in the dryer model, see
Keep “V” of divider hopper level.
1. Snug bolt top tabs (closely spaced) on inner divider hopper sections to bottom of blower skirting.
Snug bolt inner divider hopper sections together.
Use 5/16" x 3/4" galvanized bolts and nuts.
Figure 15AW Inner Divider Hopper Section
Figure 15AX Outer Divider Hopper Section
Figure 15AY Bolting top tabs of inner divider hopper to
bottom of fan skirting.
Bottom tabs are widely spaced.
Top tabs are closely space.
Bottom tabs are widely spaced.
Top tabs are closely space.