beautypg.com

Grain Systems PNEG-1626 User Manual

Instructions, Sensor replacement

background image

Date: 05-17-10

PNEG-1626

Instructions

1004 East Illinois Street • Assumption, IL 62510 • 217-226-4421

PNEG-1626

Printed in the U.S.A.
Copyright © 2009 by GSI Group
www.gsiag.com

Page 1 of 1

Sensor Replacement

Instructions for replacing a regular 602E020 moisture sensor with a “Low Noise”
602E020-D or CAT5 moisture sensor

Sensor Replacement:

1. Remove the 602E020 moisture sensor

and its wiring.

2. Install the 602E020-D or CAT5 and wire it

following supplied wiring diagram.

NOTE: The entire run of sensor cable must

be replaced for this sensor to perform
properly.

Extending Sensor Cable:

1. Use only WR-CAT5E-SH or equivalent.

2. Use a sealed type junction box for splice.

(602N217 sensor extension box.)

3. If no terminal strip is used in splice box,

solder and heat shrink all connections.

Kit contents:

1 - 602E020-D or CAT5 Sensor

1 - Pneg-1626 Instruction Sheet

Table of contents