beautypg.com

Figure 144 enabling tr-069, Table 105 tr-069 commands – ZyXEL Communications 802.11g HomePlug AV ADSL2+ Gateway P-660HWP-Dx User Manual

Page 249

background image

Chapter 17 Remote Management Configuration

P-660HWP-Dx User’s Guide

45

Follow the procedure below to configure your P-660HWP-Dx to be managed by CNM
Access. See the Command Interpreter appendix for information on the command structure and
how to access the CLI (Command Line Interface) on the P-660HWP-Dx.

"

In this example a.b.c.d is the IP address of CNM Access. You must change
this value to reflect your actual management server IP address or domain
name. See

Table 105 on page 45

for detailed descriptions of the commands.

Figure 144 Enabling TR-069

The following table gives a description of TR-069 commands.

ras> wan tr069 load
ras> wan tr069 acsUrl a.b.c.d
Auto-Configuration Server URL: http://a.b.c.d
ras> wan tr069 periodicEnable 1
ras> wan tr069 informInterval 2400
TR069 Informinterval 2400
ras> wan tr069 active 1
ras> wan tr069 save

Table 105 TR-069 Commands

ROOT

COMMAND OR

SUBDIRECTO

RY

COMMAND

DESCRIPTION

wan

tr069

All TR-069 related commands must be preceded by wan tr069.

load

Start configuring TR-069 on your P-660HWP-Dx.

active [0:no/
1:yes]

Enable/disable TR-069 operation.

acsUrl

Set the IP address or domain name of CNM Access.

username
[maxlength:15]

Username used to authenticate the device when making a

connection to CNM Access. This username is set up on the server

and must be provided by the CNM Access administrator.

password
[maxlength:15]

Password used to authenticate the device when making a

connection to CNM Access. This password is set up on the server

and must be provided by the CNM Access administrator.

periodicEnable
[0:Disable/
1:Enable]

Whether or not the device must periodically send information to

CNM Access. It is recommended to set this value to 1 in order for

the P-660HWP-Dx to send information to CNM Access.

informInterval
[sec]

The duration in seconds of the interval for which the device MUST

attempt to connect with CNM Access to send information and

check for configuration updates. Enter a value between 30 and

2147483647 seconds.

save