Transmit maintenance counter
ASCII
[GS] g 2 m nl nh:
Hexadecimal 1DH 67H 32H
Decimal
<29> <103> <50>
Description
Transmits the value of the specified maintenance counter.
• nl, nh specifies the maintenance counter number as (nl + nh x 256)
Counter number
Counter [Units]
Kind of counter
Hex
Decimal
14
20
Number of line feeds: roll paper
can be reset
14
20
Number of times energizing head: roll paper
14
20
Number of autocutter operations
14
20
Printer operation time
14
20
Number of line feeds: roll paper
cumulative
14
20
Number of times energizing head: roll paper
14
20
Number of autocutter operations
14
20
Printer operation time
• The contents of the maintenance counter are as follows:
Hexadecima
Decimal
Amount of data
Header
5FH
95
1 byte
Data
30H-39H
48-57
1-10 bytes
NUL
00H
0
1 byte
• During the transmission of block data values in the maintenance counter, the printer ignores
the real-time commands. Also, the printer does not transmit ASB even when the ASB is
enabled. Therefore, the user cannot confirm changes in the printer status during these periods.
• The counter values may be different from the actual counts depending on time differences at
power off or the occurrence of an error.