TransAct Technologies ITHERM 280 User Manual
Page 216

Programming Codes
iTherm
®
280 Programmer’s Guide
Page 214
Rev C
28-07764
Bit
Off/On
Hexl
Decimal
Status
0
Off
00H
<0>
Not used; fixed to off
1
On
02H
<2>
Not used; fixed to on
2
-
-
-
Undefined
3
Off
00H
<0>
Paper is not being fed by the
FEED
Button
On
08H
<8>
Paper is being fed by the FEED Button
4
On
10H
<16>
Not used; fixed to on
5
Off
00H
<0>
No paper out stop
On
20H
<32>
Printing stops due to paper out
6
Off
00H
<0>
No error
On
40H
<64>
Error occurs
7
Off
00H
<0>
Not used; fixed to off
Table 37 Off line Status (
Bit
Off/On
Hex
Decimal
Status
0
Off
00H
<0>
Not used; fixed to off
1
On
02H
<2>
Not used; fixed to on
2
Off
00H
<0>
No mechanical error
On
04H
<4>
Mechanical error occurred
3
Off
00H
<0>
No auto-cutter error
On
08H
<8>
Auto-cutter error occurred
4
On
10H
<16>
Not used; fixed to on
5
Off
00H
<0>
Unrecoverable error occurred
12
On
20H
<32>
Recoverable error occurred
6
Off
00H
<0>
Not used; fixed to off
7
Off
00H
<0>
Not used; fixed to off
Table 38 Error Status (
Bit
Off/On
Hex
Decimal
Status
0
Off
00H
<0>
Not used; fixed to off
1
On
02H
<2>
Not used; fixed to on
2,3
Off
00H
<0>
Paper low sensor: paper adequate
On
(0CH)
(<12>)
Paper low sensor: paper low
4
On
10H
<16>
Not used; fixed to on
5,6
Off
00H
<0>
Paper out sensor: paper adequate
On
60H
<96>
Paper out sensor: paper not present
7
Off
00H
<0>
Not used; fixed to off
Table 39 Paper Roll Sensor Status (
Function
Transmit Peripheral Status
ASCII
[ESC] u
Hexadecimal 1BH 75H
Decimal
<27> <117>
Range
n = 0
Description The [ESC] r
[GS] r command. The iTherm
®
280 return cash drawer status as specified below.
Bit
Off/On
Hex
Decimal
Status
12
The iTherm
®
280does not allow buffer recovery on unrecoverable errors. Following the recovery
process will not restore the data buffers.