beautypg.com

TransAct Technologies ITHERM 280 User Manual

Page 213

background image

iTherm

®

280 Programmer’s Guide

Programming Codes

28-07764

Rev C

Page 211

Bit

Off/On

Hex

Decimal

Status for Automatic Status Back (ASB)

0

Off

00H

<0>

Not used; fixed to Off

1

Off

00H

<0>

Not used; fixed to Off

2

Off

00H

<0>

Drawer kick-out connector pin 3 low

On

04H

<4>

Drawer kick-out connector pin 3 high

3

Off

00H

<0>

On-line

On

08H

<8>

Off line

4

On

10H

<16>

Not used; fixed to On

5

-

-

-

Undefined

6

Off

00H

<0>

Paper is not being fed by the

FEED Button

On

40H

<64>

Paper is being fed by the

FEED Button

7

Off

00H

<0>

Not used; fixed to Off

Table 29 Automatic Status Back (ASB) First Byte (Printer Information)

Bit

Off/On

Hex

Decimal

Status for Automatic Status Back (ASB)

0

-

-

<0>

Undefined

1

-

-

<0>

Undefined

2

Off

00H

<0>

No mechanical error

On

04H

<4>

Mechanical error occurred

3

Off

00H

<0>

No Auto-cutter error

On

08H

<8>

Auto-cutter error occurred

4

Off

00H

<0>

Not used; fixed to off

5

Off

00H

<0>

No unrecoverable error

11

On

20H

<32>

Unrecoverable error occurred

6

Off

00H

<0>

No temporary abnormality of the print head
temperature (high temperature)

On

40H

<64>

Temporary abnormality of the print head
temperature (high temperature) occurred

7

Off

00H

<0>

Not used; fixed to Off

Table 30 Automatic Status Back (ASB) Second Byte (Error Information)

11

The iTherm® 280 can not recover from mechanical errors without flushing the input buffer. All

print data will be lost if a mechanical error occurs.