TransAct Technologies ITHERM 280 User Manual
Page 213

iTherm
®
280 Programmer’s Guide
Programming Codes
28-07764
Rev C
Page 211
Bit
Off/On
Hex
Decimal
Status for Automatic Status Back (ASB)
0
Off
00H
<0>
Not used; fixed to Off
1
Off
00H
<0>
Not used; fixed to Off
2
Off
00H
<0>
Drawer kick-out connector pin 3 low
On
04H
<4>
Drawer kick-out connector pin 3 high
3
Off
00H
<0>
On-line
On
08H
<8>
Off line
4
On
10H
<16>
Not used; fixed to On
5
-
-
-
Undefined
6
Off
00H
<0>
Paper is not being fed by the
FEED Button
On
40H
<64>
Paper is being fed by the
FEED Button
7
Off
00H
<0>
Not used; fixed to Off
Table 29 Automatic Status Back (ASB) First Byte (Printer Information)
Bit
Off/On
Hex
Decimal
Status for Automatic Status Back (ASB)
0
-
-
<0>
Undefined
1
-
-
<0>
Undefined
2
Off
00H
<0>
No mechanical error
On
04H
<4>
Mechanical error occurred
3
Off
00H
<0>
No Auto-cutter error
On
08H
<8>
Auto-cutter error occurred
4
Off
00H
<0>
Not used; fixed to off
5
Off
00H
<0>
No unrecoverable error
11
On
20H
<32>
Unrecoverable error occurred
6
Off
00H
<0>
No temporary abnormality of the print head
temperature (high temperature)
On
40H
<64>
Temporary abnormality of the print head
temperature (high temperature) occurred
7
Off
00H
<0>
Not used; fixed to Off
Table 30 Automatic Status Back (ASB) Second Byte (Error Information)
11
The iTherm® 280 can not recover from mechanical errors without flushing the input buffer. All
print data will be lost if a mechanical error occurs.